1 Loop Addressable Fire Alarm Control Panel ETL approval control panel [FW6000] - $439.00

DESCRIPTION

FW6000 Intelligent Fire Alarm Control Panel (FACP) is the new-generation fire alarm control unit designed for application in small and medium projects. It is wall-mounted type and has the advantages of powerful function, high reliability and flexible configuration. The panel is equipped with a LCD monitor to display all the information on fire alarms, faults and various operations, which can be printed out by the built-in printer. FW6000 is a one-loop control panel with maximum 240 points, which can work together with all FW 3 series field devices.
Features:
1. This FACP uses two-wire bus system to control up to 240 addressable devices.
2. Wall mount design makes it easy to use and operate.
3. The FACP is composed of a main control module, a driver board and a communication board.
4. This FACP is compatible with the complete range of the FW series fire alarm devices like intelligent detectors, manual call point, input module, I/O module etc.
5. This FACP adopts windows-based operation menus, which are convenient and easily understood.
6. All the system functions can be realized just by simple operation to select the corresponding numbers or move the cursor.
7. The fire alarm sent out by this FACP is not only visible & audible, it can also be displayed on the LCD screen and be printed out by the built-in printer simultaneously, meanwhile, it can be recorded in the history log as well.
Specification:
1. Primary AC Power supply: 220VAC 50/60Hz
2. Main supply output voltage (VDC): 27VDC & 32VDC
3. Mainy supply output current: 2.5A at 27VDC and 3A at 32VDC
4. Minimum battery size: 2*12V required 4Ah
5. Battery charging voltage (VDC): 27VDC
6. Battery charging current: 700mA
7. COM-SG connector voltage output: 1Amp @ 24VDC
8. DC24V connector voltage output: 1Amp @ 24VDC
9. COM-SG End of Line resistor (Ohms): 10K
10. COM-HJ contacts capacity: 2Amp @ 24VDC
11. COM-HJ End of Line Resistor (Ohms):10K
12. Computer Interface: USB
13. Display: Graphical LCD 128*64
14. Operating Humidity Range: 10% to 93% relative humidity, Non-condensing.
15. Operating Temperature Range: -10C to 50C
16. FACP Dimension (L*W*D): 330mm*120mm*400mm
17. FACP Neight weight: 7.8kg

https://vedard.com/blog/how-to-set-up-fire-security-system/

 

How to set up fire security system

Part 1 Laying Pipeline
1. Common pipeline material Electric tube pipe contains galvanized steel pipe, welded steel pipe, JDG steel pipe, KBG steel pipe and so on.

2. Wiring types the meaning of the various symbols labeld on common wire and cables
NH——Refractory,pass GB12666.6 refractory test;
ZR——Flame retardant,pass GB12666.5 bundle burning test
ZA/ZB/ZC——Flame retardant Class A / Class B / Class C
WD——Low smoke and halogen free
YJ——Cross – linked polyethylene insulation
V——PVC sheathed
S——Twisted pair
B——Single stranded hard line
R—-Single stranded soft line
K——Control Cable
P——With shield
For example: WDZA-KYJY-7*1.5——Low smoke halogen free flame retardant A grade XLPE double jacket 7 core 1.5mm2 control cable.
Common used wiring types: At least flame retardant wire and cable should be used for weak-current line and fire-resistant cable should be used for the power supply line of the fire alarm system.
alarm circuit——ZR-RVS-2*1.5, NH-RVS-2*1.5, NH-RYJS-2*1.5 etc.
alarm circuit trunk——ZR-RVS-2*2.5, NH-RVS-2*2.5, NH-RYJS-2*2.5
24VDC power line——ZR-BV-2*2.5, NH-BV-2*2.5, NH-BYJ-2*2.5 etc.
24VDC power line trunk——ZR-BV-2*4.0, NH-BV-2*4.0, NH-BYJ-2*4.0
multi-line control circuit——ZR-KVV-N*1.5, NH-KVV-N*1.5 etc.
broadcast line——ZR-RV-2*1.5, ZR-BV-2*1.5, ZR-RVVP-4*1.5
telephone line——ZR-RVS-2*1.5, ZR-RVVP-2*1.5, NH-RVVP-2*1.5 open
pump line——ZR-BV-2*1.5, ZR-RV-2*1.5, NH-BYJ-2*1.5 etc.
fire hydrant open pump feedback line——ZR-RV-4*1.5, NH-BYJ-4*1.5, ZR-KVV-2*1.5
network line——ZR-RVS-2*1.5, ZR-RVV-4*1.5, cat5 etc.
3. Sharing tube principle principle: Different systems, different voltage levels, different current types of lines, should not be laid in the same tube or in the same slot.
For example: strong-current line and weak-current line should not share tube broadcast line and other line should not share tube
telephone line and other line should not share tube network communication line and other line should not share tube alarm circuit line and 24V power line should not share tube alarm circuit line and open pump line should not share tube multi-line control line and alarm circuit line, 24V power line should not share tube
Part 2 Equipment Installation
1. Circuit types
There are ring circuit, T circuit, and mixed circuit
2-wire is generally used for the circuit, some equipment requires ring circuit
Every circuit (loop) can have 100 point, 200 point, or 324 point etc. 10~20% margin should be left for each circuit

2. Detectors
detector types:
point type(Photoelectric smoke, ion smoke, temperature, complex, UV flame, combustible gas, dual band, etc.)
line type(Infrared beam, recoverable / unrecoverable temperature sensing cable, air sampling, distributed fiber, light section, etc.)
conventional detector(non-coded)intelligent detector(coded)
installation location caution:
point type(distance between ceiling, roof, wall and height from the ground) line type(laying way, distance between the roof , installation spacing) distance between other equipment and beam plate
3. Modules
surveillance module (input module, surveillance relay)
control module(output module, smoke exhaust relay)
combination module (input/output module, dual input module, dual output module, other combination module)
manual alarm button and fire hydrant button(coded/non-coded, telephone jack)
detector module(alarm relay, bus access module)
short circuit isolation module
relay module(switch module)
Installation location: in module box
4. Fire display panel
types of fire display panels:
1)LED display
2) analog display panel
3)LCD display
installation location of fire display panel: on each floor of the building
fire display panel wiring: It is connected to fire alarm control panel via RS485 line.
5. junction box, module box
calculate the size of junction box and module box
determine the installation location of the junction box and module box
The modules should be set up centrally.

6. telephone
1) multi-line telephone system N+1 line system 2N line system host capacity extension and jack
2)bus-line telephone system independent bus-line telephone system shared bus-line telephone system(can connect with fire alarm system)
line type
host capacity
module,extension and jack
Bus telephone switchboard

Multi – line telephone switchboard

7. broadcast
1) System components: recording plate, regional control panel, power amplifier, module, speaker
Power amplifier power capacity selection:
Capacity can not be less than 1.5 times the maximum capacity of broadcasts in the range of simultaneous broadcasts.
2) system mode: bus system, multi-line system
Bus system broadcast

Multi-line broadcast

Part 3 Equipment wiring

2. manual alarm button
1) non-coded manual alarm button
2) coded manual alarm button
3) with jack and without jack

3. fire hydrant button
Fire hydrant button function requirements:Open pump, alarm, lighting
1)non-coded fire hydrant button
2)coded fire hydrant button

Wiring of the pressure switch is similar to that of the non-coded fire hydrant button, just without feedback lighting.
4. Surveillance module equipment connect to surveillance module:
1) Water flow indicator
2) signal valve
3) non-coded fire hydrant button
4) fire damper
5) pressure switch
6) Water level monitoring
7) other feedback signals

5. Control module equipment connect to control module
1) elevator, floor lights
2) fan, air outlet, air valve
3) fire doors, shutter doors, file smoke hanging wall
4) alarm, sound and light alarm, broadcast circuit
5) rain valve solenoid valve
6) non-fire power cut, emergency lighting
7) other control equipment

6. Combination module The location for the combination
Types of combination modules
1) single input / single output module (each with an address point or share an address point)
2) Dual input module (one or two address points)
3) Dual output module (one or two address points)
4) Dual input / dual output module
5) Three input modules
6) four input / two output modules
7) other combinations of modules module:
1)Single input / single output module – air valve, fire doors, shutter doors, elevators and so on
2)Dual input module – flow indicator + signal valve, monitoring signal concentration
3)Dual output module – non-fire power cut, emergency lighting and so on
4)Dual input / dual output module – shutter doors and so on
5)Three input modules – monitor the signal concentration
6)Four input / two output modules – centralized monitoring and control (eg tower standard layer)
7)Other combinations of modules
7. multi-line control equipment
1) fire pump wiring

2) smoke exhaust fan wiring

Under normal circumstances, the rain valve group of electromagnetic valve, stage fire screen and other important fire facilities should also be set up multi-line linkage. Note: “Fire Regulations” only require fire pumps and fire engines in addition to automatic control, the need for manual direct control.
Part 4 Fire control center equipment
1. Fire control center equipment introduction
1) fire alarm controller (wall-mounted, cubic up, piano-style)
2) fire alarm controller components (host panel, multi-line disk, bus, circuit cards, communication cards, etc.)
3) DC power supply plate
4) fire broadcast and background music host
5) fire telephone host
6) CRT graphics display system
7) UPS uninterruptible power supply
8) Large space fire gun controller
9) electricity leakage fire alarm host
10) Level display
11) other equipment
2. the fire alarm controller capacity calculation Loop capacity (whether the detector / module is coded differently) Reserve capacity (consider fire partition) Number of loops Combined with multi-line disc,the number of bus lines Controller capacity

https://vedard.com/blog/do-not-use-water-for-these-types-fire-extinguishing/

 

Do not use water for these types fire extinguishing

Do not use water for fire extinguish

Using water to extinguish fire, that is what we generally think of when we encounter fire. But for some types of fire, do not use water to extinguish fire. Because it will spread the fire and even lead to explosion. Below is the fire types which are not allowed to use water for fire extinguishing.
1.Electrical Fire

Water is electrical conductive material, if use water to extinguish electrical fire, it will cause electric shock and may lead to person death.
So, for electrical fire, we should firstly cut off the power supply. Then use carbon dioxide extinguisher or wet quilt to extinguish the fire. Foam extinguisher is not allowed for electrical fire extinguishing cause it is conductive material as well. If the hot fired TV set or PC etc. electrical appliance meets the water, it will explode.
2.Oil cooking fire

If fire happens on oil pan, do not use water to extinguish fire! The hot fired oil will spread with fire when it meets water. So, the fire will spread suddenly. Immediately cover the fired oil pan with cover or throw wet towel, vegetables into fired oil pan to cover the fire.
3.Fuel oil or paint fire

The density of fuel oil such as gasoline and paint is smaller than water, when use water to extinguish it, the water will sink and oil or paint will rise, then the fire spread. So, do not use water to extinguish fuel oil or paint fire. The correct way is using dry powder extinguisher or sand to extinguish the fire.
4.Hazardous chemical substances fire

Most chemical substances will have a chemical flame reaction when they meet water. The substances include sulfuric acid, nitric acid, hydrochloric acid, metal potassium, sodium, aluminum, magnesium etc.
Do not use water to extinguish chemical substances fire. The correct way is using dry sand or asbestos blanket to extinguish fire.
5.Gas fire

Do not use water to extinguish gas fire! The flammable gas such as coal gas, LPG, natural gas can not dissolve in water. They are lighter than water and can not be covered by water. So, if use water to extinguish the gas fire, the fire will spread. The correct way is using wet towel or wet quilt to cover the fire. Then, quickly close the gas valve.

https://vedard.com/blog/guidance-to-shop-solar-wireless-security-system/

 Solar wireless security system is a radio frequency wireless communication system including intrusion detector, alarm horn and alarm receiver. As with other RF wireless security systems, choose the same brand when purchasing solar wireless systems to ensure wireless transmission compatibility.




From the alarm store, select HB brand alarm system manufacturer
You can see all the HB brand wireless compatible security device including intrusion detector, siren strobe, alarm bell, alarm panel, smoke alarm, gas sensor, water leakage detector, door contact, indoor motion sensor, break beam sensor. All of them can be compatible with each other. One alarm receiver of alarm bell such as HB-805A or HB-MFR or alarm panel HB-5050G/R can equip with at least 24 wireless sensors and remote controller.
Solar security systems are characterized by energy saving and ease of installation. Solar wireless break beam system can best protect outdoor vehicles and other property security and against intrusion to indoor. Its wireless transmission range can reach 500-800 meters. Alarm receivers in homes can receive alarms from detectors installed in driveways, yard fences, and walls.

The Solar Wireless Security system is an upgrade to the wired alarm system.The wireless communication strength of the product has been enhanced.The outdoor anti-interference ability of the product has been improved.The ease of installation and use of the product has been improved.
Solar wireless safety system is a professional residential, commercial and industrial safety protection system. But normal people can quickly learn to install it like professionals. The break beam has LCD calibrator to show the transmission and receiving terminals calibration status.
Choose the right security system according to the construction characteristics of the house. For example, for the gate or driveway protection can choose solar infrared detector or solar break beam sensor. Refer to driveway alarm.
Choose appropriate alarm notification equipment according to residential characteristics and safety requirements. If you are always at home, you can choose the alarm bell HB-805A. If not, you can choose app alarm HB-5050G/R.

https://vedard.com/blog/wireless-fire-alarm-system/

 

Wireless fire alarm system

The traditional fire alarm system is complicated to install, program and maintain. For the fire alarm and evacuation, fire extinguishing needs of small hotels, small businesses, factories and others, people are looking for a more convenient fire alarm system.The adoption of wireless communication technology can greatly improve the installation and maintenance of fire alarm system.

Based on the traditional fire alarm system, wireless fire alarm system expands the remote monitoring function.
Wireless networked fire alarm system is a fire monitoring and early warning system composed of independent fire detection alarm related equipment and platform all or part through wireless communication connection.It is usually composed of independent type smoke detection alarm, independent type heat fire detection and alarm, home combustible gas detector, independent type of electrical fire monitoring detector, manual fire alarm button, relay device, sending and receiving device, sound and/or light fire alarm, fire hydrant and fire water system condition monitoring field devices, and home fire safety system, on-site terminal platform and remote management platform, all or part of it.
Anyway, the wireless network fire alarm system is not applicable to the production and storage sites of gunpowder, explosive, ammunition and incendiary products. It is mainly suitable for nursing homes, welfare homes, kindergartens, nurseries, boarding schools and other dormitories, dormitory fire monitoring and alarm. Wireless fire alarm system can also be easily applied to the transformation and increase of the original fire system.
Input/output module can be used to convert wireless alarm signal to any third party fire alarm control panel. Wireless fire alarm system (including smoke detector, heat detector, gas sensor, manual call point and alarm control panel etc.) can be set as part of other any type addressable fire alarm system as addition.

Through the use of wireless fire alarm system, people can get accurate fire information more quickly. Wireless fire alarm system is equipped with voice alarm, which helps to avoid people being unconscious to sound and light alarm. Wireless Internet fire alarm can send alarm signals to multiple users in multiple ways, including phone, SMS and APP.In this way, users can be ensured to receive the alarm information and prevent the fire in time. The wireless fire alarm system complies with national fire Safety codes. Comply with building design fire code.