Debugging of automatic fire alarm system

  Before debugging the automatic fire alarm system , the specifications , models , quantities and spare parts of the equipment should be c...

How to avoid CO carbon monoxide poisoning

Carbon monoxide poisoning can cause serious damage to the brain tissue. Even if cured, it may remain a sequela of central nerve injury.
How to avoid carbon monoxide poisoning?
We need to know at what situations the carbon monoxide may produced.
  1. Coal burning
Coal burning is used for heating or cooking. If the coal is not completely burning, it will being producing amount of carbon monoxide. If the room is closed or unventilated, carbon monoxide poisoning occurs.
  1. Combustible gas water heatercarbon monoxide alarm
Combustible gas is used for water heater for some homes. If the gas water heater is installed in bathroom and with door and window closed, the gathered carbon monoxide will cause poisoning. So, it is better not installing gas water heater in bathroom.
  1. Stay or sleep in vehicle with air conditioner turning on
When the running speed of the vehicle engine is slow, the gasoline is not burning completely and will produce amount of carbon monoxide. The produced carbon monoxide will blow into the car through air conditioner.
What symptoms are carbon monoxide poisoning?
Slight headache, fatigue, dizziness, nausea is symptoms of mild carbon monoxide poisoning.
Frontal headaches, flush on face, very red lips, much sweat, fast heart rate, restless and entering into coma. That is the symptoms of moderate poisoning.
Dizziness, nausea and convulsions, unconsciousness, body temperature rising. That is the symptoms of severe carbon monoxide poisoning.
What should we do if someone has carbon monoxide poisoning?Help CO poisoning patient
Cause carbon monoxide poisoning will injure brain tissue and the poisoned person can not move or ask for help by himself.
If carbon monoxide poisoned person is found, the helper should creep to the scene and open door and windows quickly. Move the poisoned person to a ventilated and warm place and keep him or her lying.
For patients who are unconscious, the head may be tilted to one side to prevent the vomit from being sucked into the lungs causing suffocation.
Call an ambulance and send the patient to a hospital with a hyperbaric oxygen tank.
How to prevent carbon monoxide poisoning?
For the resident who uses coal to keep warm, the chimney should be installed in the room where fireplace is in.
Open door or windows when coal oven is used for cooking or heating.
Do not install gas water heater in bathroom. It should be installed outdoor or near the windows of room neighbor bathroom.
Do not sleep or stay in vehicle with door and windows closed. Should timely open window for ventilation when air conditioner is turning on for long distance driving.
Install Carbon Monoxide AlarmCarbon monoxide detector
CO Carbon Monoxide Alarm is a security detector for sensing CO and triggering sound and light alarm if the monitored carbon monoxide density reaches to set value. It can be easy installed with AC power supply or connected to home security system. Where should we install the carbon monoxide alarm? If your bedroom hallway is longer than 40 feet, install a CO alarm at both ends of the hallway.  Install at least one CO alarm near or within each separate sleeping area. For added protection, install an additional CO alarm at least 20 feet (6 meters) away from the fireplace, furnance or fuel burning heat source.

Fire Alarm Systems Maintenance and trouble shooting

Fire Alarm Systems Maintenance Schedule
The User should regularly test and mainten the fire alarm system. The BS5839-P1 makes the following recommendations.
Daily Check of fire alarm system
  1. Check that the panel indicates normal operation. If not,record any fault indications in the history log and report to the responsible person.
  2. Check that any fault records from the previous day has received attention.
Monthly Check of fire alarm system
  1. Operate at least one manual call point or detector [different device each month] to ensure the system operating
  2. Check the alarmwarning devices have operated and then reset the panel. 3. Any defect should be reported and recorded in the log book.
  3. Action should be taken to correct the defect.
Quarterly Check of fire alarm system
  1. Check entries in the log book and take any necessary action.
  2. Inspect the batteries and their connections.
  3. Operate at least one manual call point or detector [different device each zone] to ensure the system operating
  4. Check all the alarm warning devices have operated and then reset the panel.
  5. Check that all function of the control panel operates by simulating fault conditions.
  6. Visually check that structure alternation against any corrosion due to environmental effect.
  7. Any defect should be reported and recorded in the log book. Action should be taken to correct the defect.
Annually Check of fire alarm system
  1. Carry out an inspection as detail for this quarterly inspection.
  2. Every detector should be tested in the site.
  3. All cable fittings and equipment should be checked to ensure that they are secure and undamaged.
Fire Alarm Systems Trouble Shooting
  1. No indication on the panel or abnormal indication
Power is abnormal. Loose connection with switchboard.
Check and replace low voltage switch power. Check the connection to display board.
  1. Display “AC Fault” after power-up
No AC power.  Check and connect AC wire.
3. Display “Battery Fault” after power-up
Loose connection with battery. Battery discharged or damaged. Open the power box and check relative parts. Power up for more than eight hours with the AC power supply, if the fault still exists, replace the batteries.
4. Unable to register loop equipment
Bus wrong or loose connection. Check the loop
5. Some detectors can not be registered
Disconnect the bus line to the detector, measure the bus line voltage. If it is ok, then maybe the sensor and the base is not well connected. Or the detector coding is repeated or out of coding number. Re-code the detector.
6. The detector is registered but not trigger fault alarm when it is disconnected.
The detector address is bypassed. Or the fire alarm control panel is under fire alarm now. Or fire alarm control panel is fault
7.False alarm
The fire alarm control panel makes false alarm.
Reset the fire alarm control panel. If it can be reset, then the false alarm is made by accidental factors such as environment interference. If some detector triggers multiple times fault alarm, then the detector should be replaced or change the installation place. If it can not be reset, then there is problem with the detectors and connection.
8.Unable to register repeater panels
Wrong or loose connection of communication cables. Check power supply to repeaters and communication wires
9.Cannot print
Print mode is disabled. Loose connection with printer. Printer damaged Enable the print mode. Check and connect the printer well. Replace the printer.
10.Equipment fault
Equipment disconnected. Equipment damaged. Check connection. Replace equipment.
11. Loop fault
Loop is shorted. Loop is Interruption (The devices are re-established within 100s) Check the loop and repair.
12.Clock or memory fault.
External interference. Corresponding parts are aging. Check if the FACP is properly earthed. Inform our technical service
13.Some keys do not work
Check if the keyboard is locked.
14. No output from detection circuit
Remove the detection circuit, measure the outside line voltage and check whether or not it is short-circuited. If not, check bus driver board to make sure whether or not it is damaged.

Solar Wireless PIR Detectors Features

Solar wireless PIR detectors is new generation intrusion detector. It enables DIY home security more easy without wiring and without battery replace in 10 years. Solar power infrared detector is environment friendly electronic security device.
Solar power intrusion detector has solved some issues of traditional PIR detector with innovative technology. For example, this new type detector will not be interfered by same frequency band other wireless device. It will not be interfered by bad weather hot days or code days.
So, solar PIR wireless intrusion detector is easy to use and more reliable for home security and anti-theft. How can it do? What technology is adopted?
1. Solar power technology
Not need to installed outdoor.
This detector is installed indoor and powered by natural light, LED light or other indoor weakness light.
Not need adequate light source and it even can be installed in dark area. It relies on its large capacity batter (10000mA/h) for power supply.
Solar PIR intrusion detector
2. Free false alarm
Strong ability to anti-interference with FSK+FHSS signal transmission technology, wireless distance is more than 500m. When send alarm signal to alarm host, it uses multiple frequency band transmission. If one frequency band be interferenced, it automatically turn to another frequency band and without missing alarm or false alarm.
Industrial and military material is made of the intrusion detector. It has automatically environment-analysis technology to sense temperature and change sensitivity.
Pet identification and CPU analysis enables the pet immunity of this new burglary proof motion sensor.
Where is it installed?
Different types motion sensors
Solar wireless curtain PIR is installed on wall or ceiling to detect intrusion from windows, balcony, gate.
Solar wireless ceiling PIR is installed in bedroom, child room, guest room to detect motion in rooms.
Facebook Comments

Fire Alarm System Troubles Resolve Solutions

Fire alarm system is professional security equipment. Different fire security equipment manufacturer has different design coding and programming methods. But general fire alarm system design and functions are similar. Below we will list some troubles and resolve solutions for the fire alarm system programming and operation.
1. Fire Bell, Siren strobe does not react when fire alarm is triggered.
Solutions:
A.Please check whether or not the indication LED is on.
B.Please check whether or not there is fault information of the fire bell, siren strobe on the fire alarm control panel.
C.Please check whether or not 24V power is supplied for the fire bell, siren strobe.
D.Please check whether or not the fire bell control module is set as remote sound or siren strobe
E.Please check whether or not the output of fire bell, siren strobe is active on linkage setting.
2. When fire alarm is triggered, some equipment has requested reaction, but there is no reaction from on spot equipment, why?
Solution:
The equipment feedback signal should be sent by control surveillance module. So, please check whether or not the on spot equipment status is set as automatic and can be turned on by control module. If it is set as automatic, then check the feedback signal wiring and make sure it is wired well.
3. Some circuit keeps reporting fault or feedback and then disappears automatically, why?
Solution:
The caution is equipment type is not compatible or there is strong interference from the circuit. If using menu operation to test the point, the waving can be seen from the diagram curve. Generally it is cause of bad connection between circuit signal GND with earth. Please measure the resistor of the GND circuit and at normal it should be more than 5mω.
Fire alarm troubles
4. Some circuit can only trigger alarm linkage once, after that no fire alarm or feedback can be activated, why?
Solution: There is short circuit between detector or module circuit with control module. So, please check the circuit.
5. The fire alarm control panel reports main power fault and backup power fault as well?
A.Please check and make sure the main power feedback wire is well connected.
B.Please check and make sure the alarm panel power setting of power feedback type is the type of actual used power.
6. What fault can be isolated and what fault can not be isolated?
When pressing the isolate key on the fire alarm panel, it can isolates all detectors and modules which are triggering alarms. From menu setting of detectors and modules, the isolation function can isolate detectors and modules on this machine only.
The isolation function can not isolate system fault such as panel communication fault, panel power fault, interface communication fault or circuit fault, printing fault, repeat display fault etc.
7. There is no fire alarm or fault alarm report from fire alarm control panel, but the detector or module inspection indication LED is flashing.
Solutions: Maybe there is interference signal on the circuit. Please disconnect the circuit, then connect part of the circuit to system and test, repeat doing it till problem is found.
Maybe there is module or detector positive and negative polarity reversal. Please remove the circuit from the alarm panel and measure the resistor of positive phase and reverse phase.

Explosion proof Fire Alarm Gas Detector Sounder Beacon

Explosion proof products are required to be used in oil field, chemical industry factory, metallurgical industry environment. Harmful gas detector, sounder, siren strobe, beacon, fire alarm systems are used for these fields with explosion proof requirement. That is because there is explosive mixture in these environment.
There are three types explosion proof products: intrinsically safe type, flameproof type, increased safety types.
Explosion Proof zones:
zone 0: Under normal circumstances, explosive gas mixture exists continuously or for a long time.
zone 1: Potentially explosive gas mixtures may exist under normal conditions
zone 2: Under normal circumstances explosive gas mixtures does not exist, only in abnormal situations, explosive gas mixtures
may exist occasionally or in short-time.
zone 10: Under normal circumstances, the mixture of explosive dust or combustible fiber and air may exist continuously, appear frequently or exist for a long time.
zone 11: Explosive dust or mixtures of combustible fibres and air cannot occur, only occur in occasionally or for short periods in unusual circumstances.
explosion proof gas detector, sounder beacon
According to explosion gas species and Minimum detonation spark energy, the gas explosion is divided into 4 grade.
explosion gas species
According to explosion gas temperature, there are 6 groups. Check below of temperature groups and gas species.
explosion gas temperature
Explosion-proof certification mark
According to factory or mine explosion media, the minimum sparking energy, the minimum sparking temperature and explosion gas existing time, there is classification of explosion proof certification mark.
For example: ATEX form, E Ex iaIIC T4, E means Cenlecom certificate mark, Ex means explosion proof, ia means intrinsically safe type and can be installed at zone 0 area. IIC means it can be used at environment where IIC type gas exists. T4 means it meets T4 safety temperature group requirement.
Dust and water proof grade: 
Explosion proof products have dust and water proof capacity as well. It is marked as IPXX. For example: IP65 means it has totally dust resistance capacity and can accept low pressure water jet from all angles.
Vedard Security supplies explosion proof sounder, bell and lighting, siren strobe, smoke detector, heat detector, H2S detector explosion proof, beacon explosion proof, HC detector, manual call point explosion proof.
Explosion bell
The explosion proof detectors and alarms can be connected to fire alarm control panel, manual call point. The detectors are installed at chemistry factory, mines.