Featured Post

Customers frequently asked questions about Solar Beam systems

1、How many zones can connect to panel? For the moment ,we have 9 sets of host unit , the least one support 4 defense zones, the most one ...

How to set up driveway alarm systems

Entry driveway alert is necessary for flat house families safety. Even if you live in wealthy and civilized country, there is still theft and burglary. Maybe the unbalanced society is the cause for it. However, try the best to prevent crime and keep safety is the best way and only way we can do.

warning of visitors
How to set up driveway alarm systems? The system is a set of wireless driveway sensors, solar-powered photoelectric beams sensor is the typical one, and alert siren strobe or wireless receiver.
How does the driveway alert system work? When the car or someone pass through the driveway, the alert system will trigger alarm with sound and light outdoor on the wall and inside. It can be used as reminder of home owner back if it is necessary. Without getting near the house, entry action is known as alert or warning.
How is it easy and reliable to use the wireless solar-powered photoelectric beams driveway alert system? No false alarm from birds, lizards, winds or fallen leaves. No any wiring is needed for power or for signal transmitting.
There are two packages of driveway alert security system. One package is one pair beams sensor with outdoor solar-powered siren strobe. Another package is one pair beams sensor with indoor wireless receiver.

Wireless alert system

How is sensor important for smart home

Sensing technology is important for smart home system. With sensors, the environment change can be sensed and reported to controller for analysis, the controller then commands the device adjusting and responding. The smart home system is the real automatic running smart system.
How is sensor important for smart home. How does the sensing technology change and improve the smart home system functions? Below we will analyze it.

  1. Sensors provide abundant data and enable artificial intelligence of smart home system
With sensors, the smart home system will be more programmable. Home is more visible and environment change is quantized and smart home system can automatically running according to change of reality. Everything can be a virtual device and is connected. Everything is intelligent and can learn and respond. So, the smart home system can provide suitable service automatically.
  1. Sensor is connection of house appliance
With sensors, the house appliance such as lighting, curtain, air conditioner, cooker can be set according to the model. So, the home is smart.
  1. Only with sensing technology, the smart functions can be realized
Smart home system is based on home, with building management, network communication, house appliance automation controlling and comfort functions.
Only with sensing technology, the home model can be set and remote controlled.
  1. With sensing technology, no need manual operation
The smart home system can automatically respond to environment without manual operation or input. Various sensors can work together and largely improve smart home intelligence.
  1. Sensing technology is needed for products digital
The improvement of smart home system relies on digital products. Sensors adding is the way to improve the products to digital products. So, the products information can be connected, transformed, saved, judged, analyzed and executed.
  1. The sensors function can be expanded with application of smart home system
The sensors can be with multiple functions when it is used for smart home system. For example, infrared detector PIR, when it is used for burglar alarm system, it is a motion sensor only to trigger alarm. But when it is used for smart home system, it can be used as motion sensor when the system armed; it can be used as sensor light when the system is disarmed. With multiple sensors and adding logical analysis, it can be used as elders monitor alarm sensor.

FAS design notice

Fire alarm system (FAS) design is standard and coded for execution. The initial design is the same by default. But there are some important notice to take attention on the design phrase. Many posts suggest and imply how to design fire alarm systems for people starting out fire alarm system design. According to the fire alarm system project requirement, the specific details and codes of fire alarm design may be varied. But remember fire alarm system is a system detecting problems and notifying people with sound and light. So, both detection system and notifying system should work effectively.

Notice 1: About wiring circuit of FAS: there are two type wiring circuit: T circuit and ring circuit. We suggest to use ring circuit. If one detector is fault, it can be easy inspected with ring circuit and hard to inspect with T circuit. Ring circuit is more reliable than T circuit for the whole system. If circuit is cut, ring circuit system can be found with fault and T circuit may be not.
Notice 2: About stairway fire emergency broadcast. Stairwell is an independent detection area and stairway fire emergency broadcast is an independent notify area as well. The design is to improve and ensure the system security and reliability.
Notice 3: Setting up short circuit isolator. Short circuit isolator is needed for the FAS. Generally one short circuit isolator is needed for every 15 elements and not a detection circuit. That can raise the FAS reliability.
Notice 4: Every element should be numbered on the system construction drawing. It helps management of every department.
Notice 5: If the detector is installed in hidden place, such as the ceiling under the floor, then the independent indicator is needed for notification of its working status.
Notice 6: Using with sounder detector in bedroom to notify people in sleep. The public area audio video notification device may be not loud enough to wake up sleep people in bedroom, so, detector with sounder is needed.
Read more about fire alarm system design, fire alarm control panel manual at vedard alarm system support forum

Install intruder detector

Intruder detector and other types security sensors are the most important part of security systems.

There are various types intruder detectors for different environment application. They are outdoor detectors, curtain style detector, embedded curtain style detector, ceiling mounting detector, wall mounting detector, door and windows detector and photoelectric beam detectors etc.
intruder types

Why are there so many types detector and what is the difference? For accurately sensing the motion of intrusion and anti-resistance of environment interference, different types detector is required.
To maximum use the function of the detector designed and reduce false alarm or missed alarm, correctly choose and install the infrared detector is required.
  1. Choose the most suitable detector for the required functions and environment.
  2. Choose the detector for suitable installation way.
  3. Choose the detector for suitable detection area.
  4. Choose the detector for suitable installation height and location.
  5. Correctly install the detector according to user’s manual.

detectors functionsintruder detector









Detection Area and alarm zone setting
Protection areaprotection objectdetector typealarm zone and setting
Peripheryentry gatecurtain PIR, door contactdelay zone,give leaving time
after system armed
Bathroom, kitchen windowsgrating, window contactinstant zone, set according
to environment and activity
Balcony doorgrating, two-direction curtain PIRinstant zone, trigger alarm
immediately
Other windows peripherycurtain PIR, gratinginstant alarm zone,member
activity will not alarm at
home arm status
indoorliving roomspace PIR, ceiling PIRhome arm status not trigger
alarm, away arm status will
trigger alarm as instant alarm
EmergencyMaster bedroom,living roomemergency button24 hours zone, for home robbery
and illness security
safetykitchen, living roomgas leakage detector, smoke alarm24 hours zone,sense gas
leakage
and smoke

Security Service Upgrade using video alarm server with CMS

Network security service center is using a security system to receive protected areas’ security information and take action to stop crimes, prevent disaster. The security information transportation way is the core part of the security system.
PSTN telephone network is the most popular security service center network. But with development of digital communication technology, security system is developed as well with video alarm etc. PSTN network is with difficulty to transport the security signals fast and reliable.
The security service upgrade is to enable the security service with multiple data transportation network such as GSM/GPRS/TCP/IP and video alarm. Without any replacement, but with add-on of video alarm server and security management, GSM/GPRS communication module, the security service center can be upgraded.

According to the actual needs of most market environment and features of some brands wired alarm system such as Honeywell, Bosch, DSC, Focus, we have 4 system upgrade proposals. These proposals are based on principles of exist security system unchanged and upgrade the system to a efficient, practical, cost-effective security system via adding auxiliary equipment. 
1. Telephone alarm network system upgrade to fiber + MODEM network alarm network system;
2. Telephone alarm network system upgrade to GPRS \ PSTN \ TCP / IP multi-network alarm video networking system;
3. Telephone alarm network system upgrade to video alarm network system;
4, Video network system (CCTV) upgrade to video alarm network system.
Please check attachment for diagram and details of the upgrade and contact us in case you have any question. 

Alarm System Troubleshooting–Part 3 Detector

Alarm System is a security system consists of 3 parts alarm units. They are detectors, alarm control panel and CMS. We will share our working experience of alarm system troubleshooting categorized into 3 articles according to these 3 parts.
1.Perimeter Beams Detector
a. Alarm Control Panel does not alarm after connection of perimeter beams detector and trigger or alarm control panel can not be armed cause of the perimeter beams detector zone fault.
Possible causes: There is block between transmitter and receiver beams, connection error between beams detector and alarm control panel. The tamp-resistant switch is not closed or there is short-circuit or cut of the wiring, low voltage supplied. The perimeter beams detector zone is not programmed or not correctly programmed.
Solutions: Correctly enroll wireless perimeter beams detector or wire wired perimeter beams detector to the alarm control panel with EOL resistor. Check and confirm there is no short-circuit or cut of wiring and confirm the supplied voltage is more than 9V. Check and confirm the transceiver terminal is calibrated to receiver terminal and check the LED indicator to confirm it is at normal work status. Correctly program the zone attribute of the perimeter beams detector.
b. At installation and adjustment process, the beams detector keeps triggering alarm at alarm control panel disarm status and can not disarm it.
Possible causes: The wired perimeter beams detector circuit is at open status and the defense zone is set as 24 hours zone.
Solution: Check the connection of wired beams detector and alarm control panel and confirm it is close circuit with correct EOL resistor wired. Set beams detector zone attribute as normal zone if it is needed.
c. The LED calibration instruction is flashing or keeps lighting on
Possible causes: Receiver terminal and transmitter terminal is not calibrated correctly, the distance between receiver terminal and transmitter terminal is too long, there is block between receiver terminal and transmitter terminal, low voltage is supplied or tamper-resistant circuit is not closed.
Solution: Correctly wiring the signal and power lines between receiver terminal and alarm control panel, check and confirm the tamper circuit is closed. Adjust the receiver terminal and transmitter terminal angle to make sure it is calibrated. Ensure supplied voltage is more than 9V to the beams detector.
d. False alarm from perimeter beams detector
Possible causes: Voltage fluctuation is too large. Environment interference. There is water input and short-circuit caused of the detector or fault of the detector.
Solutions: Check and confirm the supplied voltage is more than 9V. Check and confirm the wiring is good. Replace the false alarm beams with good beams to confirm whether or not the beams is wrong.
false alarm2. Detector ( wired detector and wireless detector)
a. The detector does not alarm after connection to alarm control panel and triggered or the detector zone has fault and disables arm of the system.
Possible causes: The detector is not correctly connected to alarm control panel, the tamper circuit is not closed, there is short-circuit or cut of the wiring or low voltage is supplied. The detector zone attribute is not programmed correctly or not programmed.
Solution: Correctly wiring detector and alarm control panel (correct value of EOL resistor should be wired according to the alarm control panel). Check and confirm there is no short-circuit or cut of the wiring. Check and confirm the supplied voltage is more than 9V. Check and confirm the alarm indicator on the detector is off then wiring the tamper circuit closed. Correctly program the detector alarm zone.
b. At installation and adjustment process, the detector keeps alarm at alarm control panel disarm status and can not be disarmed.
Possible causes: The detector circuit is open and the alarm zone is set as 24 hours zone.
Solutions: Check and correct the wiring of the detector and alarm control panel. Set the alarm zones attribute as normal zone.
c. False alarm of the detector
Possible causes: There is environment interference such as sun light, flowing air and the detector sensitivity is set as high rate.
Solution: Install the detector correctly at proper place according to detector’s installation instruction. Adjust the sensitivity according to environment interference. Check the detector voltage. Replace another detector to test and if it still makes false alarm, then install a MW+PIR double technology or so for interference resistance.
d. Detector alarm LED keeps flashing and the alarm control panel showed fault of the detector
Possible cause: The detector battery voltage is low
Solution: Replace the battery for the detector
3. Wireless door contact makes false alarm
Possible cause: the the installing distance between the magnetic strip and alarm transmitter is too large.
Solution: Check the distance of magnetic strip and alarm transmitter and adjust it to meet requirement of door contact installation.

Alarm System Troubleshooting–Part 2 Alarm Control Panel

Alarm System is a security system consists of 3 parts alarm units. They are detectors, alarm control panel and CMS. We will share our working experience of alarm system troubleshooting categorized into 3 articles according to these 3 parts.
1. The alarm system does not alarm after system armed or forced armed and wired detector is triggered, why?
Possible causes: wiring error such as wired detector is not connected with alarm control panel correctly, short-circuit or cut of wiring between wired detector and alarm control panel, low voltage of the detector or end line resistor is not wired or not correctly wired. Programming error such as zone attribute is not programmed or not correctly programmed.
Solution: Check and confirm the wiring between wired detector and alarm control panel is good and end line resistor is wired correctly. Check the supplied detector voltage and confirm it is not less than 9V. Check the zone attribute is edited correctly.
alarm system troubleshooting
alarm control panel
  1. The alarm system does not alarm after system armed or forced armed and wireless detector is triggered, why?
Possible causes: The detector battery voltage is low. The detector is not correctly learned to the alarm control panel. The detector is not programmed into the alarm system zone or zone attribute is not programmed correctly. The distance between wireless detector and alarm control panel exceeds rated distance. There is metal block between wireless detector and alarm control panel.
Solutions: Change the battery and re-enroll the wireless detector to the alarm control panel, correctly programming the detector zone attribute. Shorten distance between wireless detector and alarm control panel. If there is metal block, please replace the wireless detector.
3. The alarm control panel can not receive remote signal and transferring signal, why?
Possible causes: Power supply is not enough for remote controller or signal transceiver, the wireless remote or transceiver is not enrolled correctly into the alarm control panel. The distance between the remote or transceiver and the alarm control panel is too long. Alarm control panel can not decode the received signal.
Solutions: Change remote battery and re-enroll the remote controller to the alarm control panel correctly. Shorten the distance between the remote control or the transceiver to the alarm control panel. If above solution does not work, there maybe problem of the wireless receive module of the alarm control panel and it should be return to factory for repair.
4. The alarm control panel makes false alarm, why?
Possible causes: the detector fault or wrong installed.
Solution:
Check which zone triggers alarm and check the detector.
5. The alarm control panel makes sounds at normal work status.
Possible causes: The alarm control panel can make sounds of alarm, fault alert, delay arm sound, alarm delay sound etc.
Solution: Check and identify which sound the alarm control panel made then solve the problem according to the sound. If no alarm is triggered by detector and no instruction is made to the alarm control panel and it makes sound, then there maybe the alarm system error.
6. External siren is wired to the alarm control panel, but it does not sound when alarm control panel alarms.
Possible cause: the Positive and negative wiring between siren and control panel is reverse or short-circuit. The siren voltage is low (less than 12V). The external siren is not programmed or correctly programmed to the alarm system.
Solutions: Check and confirm the wiring is correct. Check and confirm there is 12V voltage output to the siren when the system alarms. If not, please program the system and turn on the external siren. If all above is ok but still no output from the external siren, please change a siren to test or change a alarm panel to test.
7. The alarm control panel does not dial alarm receiving number when it alarms.
Possible causes: strong interference or short-circuit, cut of the telephone line. The receive phone number and communicate format, communicate grade is not programmed correctly to the alarm system. The telephone theft function is turned on.
Solutions: Check and confirm the telephone line is good without strong interference, short-circuit and cut. If additional code is needed for outline dialing, please add it to the receive phone number when program it.
8. The alarm control panel does not dial CMS telephone number when it alarms
Possible causes: strong interference or short-circuit, cut of the telephone line. CMS telephone number is not correctly programmed into the alarm system or user code is not enrolled or not correctly enrolled.
Solution: Check and confirm the telephone line is good without short-circuit and cut. Check and confirm the CMS number including communicate format and grade and user code is programmed correctly. If all above is good and problem still exist, then please check the interference of the telephone line. CMS communication is data communicate and strong interference may lead to communication interruption.
Conclusion: the updated new technology alarm control panel has voice, LCD menu, graphic prompt and low battery alert. So, alarm system troubleshooting is easy and the system has self-check maintenance program. So, alarm system is not coded and easy to operate than before.

Alarm System Troubleshooting–Part 1 CMS

Alarm System is a security system consists of 3 parts alarm units. They are detectors, alarm control panel and CMS. We will share our working experience of alarm system troubleshooting categorized into 3 articles according to these 3 parts.
1. CMS machine can not receive all users’ alarm information.
Possible causes:
problems of telephone line network communication such as strong interference or loud noise on the telephone line, short or cut of the telephone line, the burglarproof switch on the telephone is turned on or telecommunications office network failure.
Problem of alarm control panel CMS communication programming error.
Problem of the CMS network such as serial port is shut off on the software, serial port connection error, serial port damage or PC fault.
Solutions: Check whether or not telephone line is cut or with short-circuit. Shut off burglarproof switch on the telephone. Confirm the alarm control panel CMS communication programming is correct including CMS telephone number, CMS communication grade, CMS communication format, user code, alarm report option. Turn on serial port on the CMS software, connect the serial wiring correctly, confirm the serial port is good. Check and confirm the PC can work properly. Check whether or not the CMS software is trial version and trial time is due from system log.

alarm system fault
alarm system trouble shooting
2. CMS machine can receive alarm information, but the alarm information can not pop-up.
Possible causes: user information does not exist on CMS software. Serial port is shut off or serial connection error, serial port damage.
Solutions: Add user information into the CMS software, turn on serial port and correctly connect the serial wiring, check and confirm the serial port is good.
3. CMS machine can receive alarm information, but can not report it to police center or forward to other department.
Possible causes: problems of telephone line network such as strong interference, cut or short-circuit of the telephone line or communication failure of the telecommunication office.
The forwarding telephone number is not correctly filled into the CMS software.
Solutions: Check and confirm telephone network is good and with good communication. Check and confirm the forwarding telephone number is correctly filled into the CMS software.

Conclusion: CMS for security service center includes software and hardware and it requires carefully programming and setting to ensure its proper work.

Smoke Alarm types and connection

Smoke alarm is important component of fire alarm system. And it is part of home security systems.
The smoke detector alarm can be used with fire alarm system or burglar alarm system or independently sound and light alarm on-spot without connection with any alarm systems.
So, there are 4 types of wired smoke alarms. (same as heat detector, CO detector and compound detector). The connection way is different for different types smoke detector alarms.
Correct connection is required to ensure proper work of smoke alarm. Otherwise, danger will be heavier with non-work smoke detector alarm.
We need to buy correct type smoke detector to work with our exist alarm systems. And we need to wire the smoke alarm according to the detector’s manual and alarm receiver’s manual as well.
Below we will introduce these 4 types smoke alarm and connection ways (Smoke alarm type is HST brand as example. The HST brand smoke detector can be bought at Vedard Alarm Store)
Type 1: Independent Smoke Alarm.
The independent smoke detector alarm doesn’t need wire connection. It makes sound and light alert when smoke density reaches to alarm limit. The independent smoke alarm can be battery powered or AC powered with battery power backup.
Type 2: Bus type coded addressable smoke alarm
There are 4 terminals and only terminal 1 and 3 are non-polarity connected to 2-wire bus type fire alarm control panel L1 and L2.
Smoke Alarm non-polarity 2-wire connection
Non-polarity 2-wire Smoke alarm systems

2-wire bus type smoke alarm connection
wire 2-wire bus type smoke alarm

Type 3: Conventional Smoke Alarm
It is 2-wire and non-polarity connection with conventional fire alarm control panel zone+ and zone-. Multiple detectors terminal 2 and 3 are connected to zone- in series. The terminal 2 is connect with terminal 3 of next detector. This connection way will monitor the zone status and report detector error, detector missing to alarm panel. Current limiting EOL resistor is required to wire and the end of the circuit.
Conventional 2-wire Smoke Alarm System wiring
2-wire Smoke alarm wiring with Conventional Fire alarm panel

Type 4: Relay output smoke detector for connection with home alarm system.
It is 4-wire connection. There are 4 terminals on the detector. They are relay output com terminal, relay output NO/NC terminal (default NO), DC power- terminal and DC power+ terminal.
The DC power terminals are connected to AUX of alarm panel and relay outputs are connected to N/O or N/C terminal of the alarm panel. EOL resistor is required to connect to the end of the circuit as well. Please wire this type smoke alarm according to home security alarm panel requirement.
Below is example of home alarm system N/O and N/C wiring requirement.
Smoke detector wiring to N/O or N/C home alarm control panel zone
Home Security Alarm System N/O, N/C contact wiring with smoke detector

Connect 4-wire smoke detector to home security alarm panel
4-wire with relay output Smoke detector connecting with home security alarm panel

Above is example wiring of 4 types wire Smoke detector alarms. Many other brands smoke detector wiring is the same way. But wiring according to manufacturer’s manual is the correct way. For proper work of the smoke detector alarm, please remember to study the smoke detector carefully and install it correctly.

Pet immune Motion Detectors and the technology

Pet immune motion detectors are required to be installed in house where pet is living. The pet immunity motion detector can identify moving of pet and human. So, it can avoid false alarm caused by pet movement.
Intrusion Detector PET Immunity
home security system

Security systems manufacturers are adopting new digital technology to make pet immune motion detectors.
Generally, there are 2 ways of pet immunity technology. One way is changing design of Fresnel lens. The fresnel lens will refract or reflect Pyroelectric infrared signal to PIR. It will divide the detection area into a number of bright and dark regions. Changing the area division way can reduce the false alarm caused by small pet. But the effective is minimal.
Another way to reduce false alarm caused by pet is MCU processing. The MCU will collect the detected infrared signal. Then it compares that with sample signal of human movement. It analyzes the signal cycle, volumn, polarity. If the detected frequency range is 6-12Hz, the system judges an activity as a pet activity and does not generate an alarm. If the detected frequency range is 0-5Hz, the system generates an alarm.
There are maximum 15kgs, 20kgs, 35kgs pet immune motion detectors. Home owners should select the corresponding one to fit the pet weight.
Correctly installing the motion detector is important to reduce false alarm. There are installation note for pet immune motion detectors. It is required to install the detector according to the manual.
There are 4 notes when install the motion detectors.
1. Installing height
Install the motion sensor at required installing height. Otherwise, the detection distance may be shorten. The pet immunity effectiveness will be decreased.
2. Installing angle
3. Installing place
PIR motion detector should be avoid installing at some places where interference may be generated.
4. Installing direction
It is best to keep potential intrusion direction and detection area of PIR as 90 degree.
Digital technology is developing. So, in the future, the motion detector will be more intelligent and easy to use.

Program Alarm Systems Solar Beams Detectors

Program Alarm System with Solar Beam Sensors
perimeter beams
Solar beams perimeter security sensor

(HB-T001Q2;HB-T001Q3)
1. Press the switch(at the back of the sensor) 1 time to turn on the sensors. (if work normally,the indicator light will on)
2. Keep the Transmitter aligned with the Receiver (if work normally,the indicator lights will blink)
3. Trigger the beam sensors by thick materials(block up all the infrared beams)
(if work normally,the receiver’s light will on) 4.connect the beams to the host(reference to the hosts’ manuals)
alert products
community security perimeter intrusion alert products

(HB-T001Q3+;HB-T001Q4;HB-T001Q6;HB-T001Q8)
【Notice 】HB-T001Q3+ has LCD calibrator,but don’t have on site alarm function
1.Press the switch(at the back of the sensor) 3-10 times to turn on the sensors. (if work normally,the indicator light will on and there are 3-6 “di” beep prompt)
【Notice1 】if press the switch 3 times to turn on: there are 5 seconds alarm voice while the beam sensors be triggered; if 4 times,there are 15 seconds;if 5 times,there are 30 seconds;if 6 times,there are 60 seconds;if 7-10 times,no alarm voice.
All the setting will take effect after 1 hour,within 1 hour,there are 5 seconds alarm voice while the beam sensors be triggered.
2.Keep the Transmitter aligned with the Receiver (if work normally,the indicator lights will blink and there are 6 “dididi” beep prompt) 3.Trigger the beam sensors by thick materials(block up 3 infrared beams) (if work normally,the receiver’s light will on;Notice,if the sensors are in on site alarm mode,the sensors will alarm by the speaker,if in mute mode,no alarm voice ) 4.connect the beams to the host(reference to the hosts’ manuals)
Garden Lights&Beam Sensors
Alarm and garden light
Garden light and alarm

(HB-T002A8)
1.Press the switch(below the LED light)3-10 times to turn on the sensors.
(if work normally,the indicator light will on and there are 3-6“di”beep prompt) 【Notice 】there are 2 switches below the LED light,one is useful,the other one is useless.please press the useful switch to turn on the sensors.you can hear the beep while you press the useful one.
2.Keep the Transmitter aligned with the Receiver
(if work normally,the indicator lights will blink and there are 6“dididi”beep prompt)
You can find the location of the infrared beam by the marks or the indicator light
3.Trigger the beam sensors by thick materials(block up 3 infrared beams) (if work normally,the receiver’s light will on)
Cover all the solar panel of the LED light by thick materials,and the LED light on 4.connect the beams to the host(reference to the hosts’manuals)
Wireless alarm long range
Wireless alarm repeater

(HB-ZFQ)
Total 2 buttons(Status Key and Erase Key)
Total 4 indicators(Run,RF,Learn,Erase)
How to connect detectors or remote controllers to the Repeater:
1. Power on,”Run”light on.
2. Press the Status Key 3 times,”Learn”light on(means the repeater is on learning mode)
3. Trigger the detector or remote controller,”Learn”blink once and a beep prompt. One Repeater can connect 50 pieces detectors or remote controllers,so please connect the other ones by the same way
4. Press “Status Key” once,Exit the learning mode,and”Learn”light off
5. If work normally,“RF”light will blink while you trigger the detectors or remote controllers. How to delete detectors of remote controllers
1. Power on,”Run”light on
2. Press the Status Key 3 times,”Learn”light on
3. Delete one detector(the recent one)–Press”Erase Key”once,and”Erase”light on 1 second.
Delete all the detectors–Press”Erase Key”3 seconds,”Erase”light on and a beep prompt. How to set the grade of the repeater: At present,the repeater has 4 grades,and the grade can be set by the DIP switch;(factory default is grade 1—the”1”switch is on the”ON”direction,the other switches are on the opposite direction;if you want to set the repeater to grade 2,make the”2”switch on the”ON”direction,and the other switches on the opposite direction;So on…)
【Notice 】Make sure the repeater is on Grade 1 when you connect the detectors to it.
Grade 1 Repeater only can forward the signal from the Detectors;Grade 2 Repeater only can forward the signal from Grade 1 Repeater;Grade 3 Repeater only can forward the signal from Grade 2 Repeater;Grade 4 Repeater only can forward the signal from Grade 3 Repeater;But Alarm host can receive the signal from all the repeaters and detectors.
Solar beams accessory
Solar beams adapter

(HB-ZJQ-3)
Total 9 indicators,1 RUN light and 8 zone Lights.
How to connect the detectors
1. Open the enclosure of the adapter,and connect the power cables (If work normally,the Run light blink)
2. Set the DIP switch to connect the detectors;there are 8 DIP switches corresponding 8 zones; For example:connect the detectors to zone 1 Make the DIP switch 1 to ON direction,and the indicator of zone 1 light on,and”Run”light off.(means the Adapter is on learning mode) Trigger the detector,if“Run”blink,connect successfully(each zone can connect 6 pieces detectors at most). Make the DIP switch 1 to figure direction,and the indicator of zone 1 light off,and”Run”light on.(means the Adapter exit the learning mode)
3. If work normally,the light of zone 1 will on for 30 seconds while you trigger the detector(it means the output of zone 1 will keep 30 seconds)
4. Connect the detectors to other zones by the same way. How to delete the detectors
1. Power on the adapter,and“Run”light blink
2. Set the DIP switch to delete the detectors(for example:delete the detector of zone 1) Make the DIP switch 1 to ON direction,and the light of zone1 on,”Run”light off.
3.Delete all the detectors–Press”Delete Key”2 seconds,the light of zone 1 blink.
4.Delete detector of other zones by the same way.
Solar horn alert product
Solar Siren strobe

(HB-JHD-2)
Total 4 buttons(On/Off Key;Learning Key;Delete Key;Choose Sound Key) How to connect detectors and remote controllers
1.Press the On/Off Key 3-10 times to turn on the siren. (if work normally, there are 3-6“di”beep prompt)
【Notice1 】if press the On/Off Key 3 times to turn on,the siren will alarm 5 seconds while sensors be triggered;if 4 times,the siren will alarm 15 seconds;if 5 times,the siren will alarm 30 seconds;if 6 times,the siren will alarm 60 seconds;if 7-10 times,no alarm voice.
【Notice2 】If there are 3”di~~”long beep prompt while you turn on the siren,it means the siren is
Low battery or the solar panel was covered by thick materials; All the setting will take effect after 1 hour,within 1 hour,the siren will alarm 5 seconds while sensors be triggered.
2. Press the”Learning Key”once,”Learning Key”light on and a beep prompt (means the siren is on Learning mode)
3. Trigger the sensor or press the arm key of remote controller,”Learning Key”light off and a beep prompt(connect successfully)
4. Connect other sensors or remote controllers by the same way
(press“Learning Key”once,trigger the sensor) How to delete sensors and remote controllers
1. Turn on the Siren.
2. Delete one sensor(the recent one)–Press”Delete Key”once,and”Delete Key”light on 1 second and a beep prompt. Delete all the sensors–Press”Delete Key”3 seconds,”Delete Key”light on and a long beep Prompt.
How to choose the alarm voice(total 2 sounds,one is doorbell,one is Alarm)
1. Turn on the siren
2. Press the”Choose Sound Key”once,the sound you heard is the one you choose.
【Notice 】The operations of Learning,Deleting,Choosing Sound must be operated within 1 hours
after turn on the siren.if after 1 hour,you should restart the siren to operate.
GSM and PSTN alarm system
Smart home alarm system

(HB-BJQ-560A/B)
How to connect sensors 1.Press“SETUP”Key 2.Enter password“123456#” 3.Enter password“12*48#” 4.Enter zone number“000#—559#”(total 560 wireless zones) 5.Trigger the sensors
How to connect remote controllers 1.Press“SETUP”Key 2.Enter password“123456#” 3.Enter password“12*48#” 4.Enter zone number“10#—13#”(total 4 remote controller zones) 5.Press the arm key of the remote controller
How to set Phone Number —–total 3 modes:fixed phone mode;mobile phone mode and message mode Fixed Phone Mode: 1.connect the phone line 2.open the fixed phone mode(Setup—123456#—51#1#) 3.enter phone number(10#phone number#;can set total 4 phone numbers.the code is 10#—13#)
Mobile Phone Mode 1.insert the SIM card 2.open the mobile phone mode(Setup—123456#–52#1#) 3.enter phone number(10#phone number#;can set total 4 phone numbers.the code is 10#—13#)
Message Mode
1.insert the SIM card
2.open the message mode(Setup—123456#–53#1#)
3.enter message number(14#message number#;can set total 4 message numbers.the code is 14#—17#)
burglar alarm system program
LCD program alarm system

(HB-G250)with keyboard
How to connect sensors 1.Press“###” 2.Enter password“112233#” 3.Enter password“12*48#” 4.Enter zone number“000#—999#”(total 1000 wireless zones) 5.Trigger the sensors
How to connect remote controllers 1.Press“###” 2.Enter password“112233#” 3.Enter password“12*48#” 4.Enter zone number“10#—14#”(total 5 remote controller zones) 5.Press the arm key of the remote controller
How to set Phone Number 1.connect the phone line 2.Press”###” 3.Enter password”112233#” 3.enter phone number(10#phone number#;can set total 4 phone numbers.the code is
10#,11#,17#,18#)
10#-11#:user’s number code
17#-18#:alarm center number code
4.enter”1#”,open the phone mode
Wireless LCD alarm receiver
LCD alarm wireless receiver

(HB-2020 series and HB-3030 series)
Total 4 buttons(up down left right) How to connect detectors
1. Long time press“UP”key,and power on
2. Press”Left”key to select zone number(total 100 wireless zones,the code is 00–99)
3. Press“UP”key once,a beep prompt
4. Trigger the sensors,if successful,2 beep prompt.
5. Press “Right”key to choose the
6. Press “Down”key to exit setting mode How to connect remote controllers
1.Long time press“Down”key,and power on
2.Press”Left”key to select zone number(total 4 wireless zones,the code is 00–03)
3.Press“UP”key once,a beep prompt
4.Press the arm key of the remote controller,if successful,2 beep prompt.
5.Press“Down”key to exit setting mode How to set phone number 1.connect the phone line and phone ,and then power on 2.long time press the phone set key 3 seconds,and release the phone set key while you heard a
beep prompt 3.handle the phone to set:
Enter password”000000”,a beep prompt
6 user numbers,the code is 11#—16#,for example 11#phone number#
2 alarm center numbers,the code is 17#—18#,for example 17#phone number#
4.enter”0#”to exit setting mode